Anticorrosive Coatings for Steel
Corrosion protection comes from a coating system, not a single tin of paint: a properly prepared surface, a primer suited to the metal, and a topcoat built to the right dry film thickness for the environment. Marindec manufactures each layer in Alberton, Gauteng, in 1L to 200L packs.
1. Prepare the surface
Every Marindec datasheet sets the same conditions: the substrate must be dry and free of dirt, dust and oily residue, at least 3°C above the dew point, and cleaned by sandblasting or sanding. For exterior and industrial steel, solvent clean and grit blast to Sa 2½. See the surface preparation guide and Armourphos Cleaner.
2. Choose the primer for the metal
| Substrate | Primer | Film build (DFT) | Overcoat |
|---|---|---|---|
| Mild and structural steel, general | FPW15 Fast Dry Primer | 20–35 µm | within 2 h |
| Steel, anti-corrosive duty | ZPPW15 Fast Dry Anti-Corrosive Primer | 20–35 µm | within 2 h |
| Galvanised iron and zinc-coated steel | Galvanised Iron Primer | 50–60 µm | overnight |
| Bare steel needing an etch primer; aluminium and other non-ferrous metals | EPS15 Etch Primer | 10–15 µm | after 1 h |
Never put red oxide primer on galvanised steel or aluminium. Use the galvanised iron primer or an etch primer. The primer selector covers every pack size.
3. Build the topcoat for the environment
| Topcoat | Best for | Film build (DFT) | Notes |
|---|---|---|---|
| Fast Dry Enamel | Machinery, steelwork and equipment indoors and outdoors | 20–45 µm | Touch dry ~10 min. Over FPW15, ZPPW15 or etch primer. |
| AGRIP30+ High Build | Steel in harsher exterior and chemical environments | 20–45 µm | Primer and finishing enamel in one; a primer is only needed for higher film builds. |
| 2K Polyurethane | Long-life exterior finish with very good weathering | 35–45 µm | Two-pack 7:1. Use over a 2K polyurethane or epoxy primer, not an alkyd primer. |
| Hammertone | Equipment where a textured finish hides surface marks | 25–35 µm | Over ZPP, ZPPW, FPW or etch primer. |
4. Check the film thickness
Most premature corrosion comes from films that are too thin at edges, welds and corners. Measure wet film thickness while you apply and dry film thickness afterwards. The film thickness guide explains how. Practical coverage is 50–70% lower than the theoretical spread rate on the datasheet, so order accordingly.
Where these systems are used
- Structural steel, gates, fencing and steel fabrication
- Mining, farming and plant equipment
- Transport bodies, trailers and refrigeration units (transport enamel)
- Hot surfaces up to 400°C (heat resistant aluminium)
Not sure which system you need? Request a quote with the substrate, environment and area. Quotes usually come back the same working day.